Test data & evidence

What we measured, and what it does not cover

Three evidence tiers, kept apart on purpose: film-level material data, panel-level thermal performance, and finished-device safety records. A figure from one tier is never used to support a claim in another.

Request full reports (NDA)

1 · Film-level data

Measured on a film sample by a third-party laboratory. This is material data, not a product rating.

PropertyValueReportScope
Normal total emissivity≥ 0.88(2022)WT-HW-00529Film sample only
Electric-to-radiant conversion efficiency68% (double-sided)(2022)WT-HW-00529Film sample only
Testing bodyNational Infrared & Industrial Electrothermal Products Quality Inspection & Testing Center (Wuhan)(2022)WT-HW-00529Third-party laboratory
MethodsJG/T 286-2010 / GB/T 7287-2008(2022)WT-HW-00529As stated in the report
Report date2022(2022)WT-HW-00529Predates YB/T 6493-2026
Cover of test report (2022)WT-HW-00529 issued by the National Infrared and Industrial Electrothermal Products Quality Inspection and Testing Center, Wuhan
Report cover, (2022)WT-HW-00529
Results table from report (2022)WT-HW-00529: normal total emissivity 0.88, electric-to-radiant conversion efficiency 68% double-sided
Results table: emissivity 0.88, conversion efficiency 68% (double-sided)
Spectral emissivity curve from 4 to 25 micrometres from report (2022)WT-HW-00529
Spectral emissivity curve, 4–25 μm (film sample)

Pages reproduced from the original report. Results apply to the film sample tested.

2 · Panel-level data

One specific panel build, measured on the receiving plane. This applies to that panel, at those conditions — not to every panel we make.

MetricResultNote
Measurement points2200.5 × 1.1 m receiving plane
Lowest point≥30.9 °CEvery measured point
Mean33.22 °CAcross 220 points
Full range6.00 °CMax minus min
Points above 37 °C0None
Input power200 W ratedAt rated power
Floor layerFarm’s own reflective floor layer installedAs installed on site
Room temperatureNot recordedStated limitation

Source: piglet creep heating panel, 220-point thermal map. Read the case study →

3 · Finished-device safety records

Safety test records exist for consumer devices only. They are not applicable to B2B products, modules or bare film.

RecordApplies toStatus
Finished-device safety test records Consumer devices only — not applicable to B2B products In progress

Test methods

  • GB/T 7287-2008 — used for the film-level measurements in report (2022)WT-HW-00529.
  • JG/T 286-2010 — used alongside GB/T 7287 in the same report.
  • 220-point thermal grid — the panel result comes from a 220-point measurement across the 0.5 × 1.1 m receiving plane at rated power.

The 2022 report predates YB/T 6493-2026, so it was not produced under that standard. Read what the standard covers →

What we do not claim

  • No medical or health claim. Nothing here treats, prevents or diagnoses any condition.
  • No energy-saving percentage. We do not publish a “% less energy” figure without measured whole-system data.
  • No certification we do not hold. Where a certificate is pending, the table above says “In progress”.
  • No finished-product claim from film-level data. A film sample result does not qualify a module, panel or appliance.

Certification status

Current status, stated plainly. Nothing below is held yet.

CertificationStatus
CEIn progress
ULIn progress
CSAIn progress
IP ratingIn progress